Mini Split Wire Size & Circuit Breaker Chart

Use this quick lookup chart to find standard wire gauge, circuit breaker ampacity, and disconnect box requirements for standard residential ductless mini-split systems under typical 50-foot runs.

BTU Capacity Voltage Typical MCA Typical MOP Required Wire Circuit Breaker Disconnect Box
9,000 BTU (115V) 115V 12A 15A 14 AWG Copper 15A Single-Pole 30A Non-Fused
12,000 BTU (115V) 115V 16A 20A 12 AWG Copper 20A Single-Pole 30A Non-Fused
12,000 BTU (208/230V) 230V 9A 15A 14 AWG Copper 15A Double-Pole 30A Non-Fused
18,000 BTU (208/230V) 230V 16A 20A 12 AWG Copper 20A Double-Pole 30A Non-Fused
24,000 BTU (208/230V) 230V 21A 30A 10 AWG Copper 30A Double-Pole 30A Non-Fused
36,000 BTU (208/230V) 230V 32A 45A 8 AWG Copper 45A Double-Pole 60A Non-Fused

*220V, 230V, and 240V Terminology: In residential electrical branch wiring, 220V, 230V, and 240V refer to the same nominal single-phase utility service. Sizing rules, conductor gauges, and breaker sizes apply identically to all equipment labeled 220V, 230V, or 240V.

Need an exact wire run distance calculation?

Calculate custom voltage drop for runs up to 150 feet with our free interactive tool: